Title of article :
Notable size effects on very high cycle fatigue properties of high-strength steel
Author/Authors :
Furuya، نويسنده , , Yoshiyuki، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
5234
To page :
5240
Abstract :
Very high cycle fatigue (VHCF) properties were compared between two types of specimens: enlarged specimens and our standard specimens. Fatigue tests were conducted by ultrasonic fatigue testing; the material used was commercial spring steel. All tests ended in internal fracture, with large-size effects observed, i.e., the enlarged specimens showed lower VHCF strength than the standard specimens. Most of the internal fracture origins were oxide-type inclusions that were larger in the enlarged specimens than in the standard specimens, indicating the size effect to be caused by the difference in oxide-type inclusion sizes at the origins of internal fractures. The large-size effect strongly urges the use of large specimens when conducting VHCF tests on high-strength steel. Moreover, the large-size effect implies that fatigue strength cannot in this case be determined using the conventional S–N curve approach, since the S–N curve depends on the specimen size. The evaluation of the VHCF strength thus needs two steps: an estimation of the maximal inclusion size, followed by an estimation of the VHCF strength based on the maximal inclusion size.
Keywords :
Fatigue , steel , Internal fracture , Size effect , inclusion , Ultrasonic fatigue testing
Journal title :
MATERIALS SCIENCE & ENGINEERING: A
Serial Year :
2011
Journal title :
MATERIALS SCIENCE & ENGINEERING: A
Record number :
2167724
Link To Document :
بازگشت