• Title of article

    Anti-coincidence rejection of SiPM dark pulses for improved detection of low energy radiation

  • Author/Authors

    Bencardino، نويسنده , , Raffaele and Eberhardt، نويسنده , , John E. and Preston، نويسنده , , Rhys، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    4
  • From page
    497
  • To page
    500
  • Abstract
    Neutron and gamma detectors of the CSIRO air cargo scanner are based on scintillators readout by photodiodes (PD). The scanner imaging resolution is limited by the scintillator size. It, in turns, is limited by the number of interactions that can be detected by the PD. Silicon photomultipliers (SiPM) could be used in place of PDs to improve the neutron and gamma detector efficiency. It would ultimately improve the scanner performance in terms of speed, cargo size and image quality. ent use of SiPM requires gain stabilisation and dark counts suppression. This work presents a technique to strip the dark counts and the electronic noise off the genuine source-induced spectrum. The method requires the use of a pair of SiPM coupled to the same scintillator. By rejecting the events not detected by both the SiPMs, the background counts were reduced by more than 99%.
  • Keywords
    SiPM , rejection , Dark counts , Cargo scanner , Coincidences
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2010
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2170263