• Title of article

    Praseodymium activation detector for measuring bursts of 14 MeV neutrons

  • Author/Authors

    Meehan، نويسنده , , Tim and Hagen، نويسنده , , E.C. and Ruiz، نويسنده , , C.L. and Cooper، نويسنده , , G.W.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    4
  • From page
    397
  • To page
    400
  • Abstract
    A new, accurate, neutron activation detection scheme for measuring pulsed neutrons has been designed and tested. The detection system is sensitive to neutrons with energies above 10 MeV; importantly, it is insensitive to gamma radiation <10 MeV and to lower-energy (e.g., fission and thermal) neutrons. It is based upon the use of 141Pr, an element that has a single, naturally occurring isotope, a significant n,2n cross-section, and decays by positron emission that result in two coincident 511 keV photons. Neutron fluences are thus inferred by relating measured reaction product decay activity to fluence. Specific sample activity is measured using the sum-peak method to count gamma-ray coincidences from the annihilation of the positron decay products. The system was tested using 14 and 2.45 MeV neutron bursts produced by NSTec Dense Plasma Focus Laboratory fusion sources. Lead, copper, beryllium, and silver activation detectors were compared. The detection method allows measurement of 14 MeV neutron yield with a total error of ≈18%.
  • Keywords
    Activation detector , Dense plasma focus , 141Pr , Sum-peak , neutron detection
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2010
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number