Title of article
Picosecond timing using avalanche photodiodes operated near breakdown
Author/Authors
Fischer، نويسنده , , P and Henneberger، نويسنده , , R and Lindenberg، نويسنده , , W and Trauth، نويسنده , , M and Wermes، نويسنده , , N، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
4
From page
789
To page
792
Abstract
Using dark rate dependent feedback and quench circuitry, avalanche photodiodes have been stably operated at voltages close to breakdown and above. Exploiting the large amplification in such an operation, time resolutions of 15 ps for 108 incident photons have been measured at temperatures around 0°C.
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1996
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2171358
Link To Document