Title of article
3D investigations of the 35 MV tandem Vivitron
Author/Authors
Thiery، نويسنده , , Y. and Gao، نويسنده , , J. and Le Duff، نويسنده , , J.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
6
From page
21
To page
26
Abstract
Trying to understand the sparking on the metal bars which connect the discrete electrodes on the same radial position, the 3D program Antigone [1] has been used to model the Vivitron structure (which includes terminal electrode, tank, discrete electrodes (DE), and, of course, metal bars) and to find out the electric field distributions on the surface of the electrodes. 3D calculation shows that the maximum electric field happens on the metal bars instead of the edges of the discrete electrodes so in disagreement with the initial machine design expectation. According to the numerical simulations, 20 MV appears as the limit for the terminal voltage with the present machine structure. Improvements on the metal bars seem necessary if nominal voltage is still envisaged.
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1996
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2173262
Link To Document