FN-tandem accelerator in Bucharest after the seismic protection system installation
Author/Authors :
Marinescu، نويسنده , , L and Petrascu، نويسنده , , M and Dima، نويسنده , , R and Serban، نويسنده , , D، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
5
From page :
82
To page :
86
Abstract :
Subsequent to the installation of the seismic protection system in the HVEC FN-tandem accelerator in Bucharest, observations have been made of the efficiency of the protection devices. Performance and improvements of the new voltage divider are discussed. The SF6 content of the insulating gas is shown to be conveniently measured using the elastic recoil technique and a robust ioniser heater is described for the HICONEX source.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1996
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2173988
Link To Document :
بازگشت