Amos، نويسنده , , N. and Cremaldi، نويسنده , , L. and Finocchiaro، نويسنده , , G. and Gobbi، نويسنده , , B. and Ng، نويسنده , , K.K. and Manzella، نويسنده , , V. and Peskov، نويسنده , , V. and Rajagopalan، نويسنده , , S. and Rubinov، نويسنده , , P. and Schamberger، نويسنده , , D. and Sellberg، نويسنده , , G. and Steffens، نويسنده , , J. and Tilden، نويسنده , , R. and Wang، نويسنده , , P. and Yu، نويسنده , , Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
9
From page :
342
To page :
350
Abstract :
The performance of a telescope of micro-strip gas chambers (MSGC) has been studied in a beam of pions. Detectors with different anode pitch and with different substrates have been operated using several gas mixtures. The position resolutions obtained by reading out the cathodes for the 200 μm pitch is 42 μm. For the 400 μm pitch detectors the resolution is 42 μm after correcting the centroid positions with a function derived from the data.