Title of article :
Measurement of radiation damage on an epoxy-based optical glue
Author/Authors :
Huang، نويسنده , , H.C and Peng، نويسنده , , K.C and Sahu، نويسنده , , S.K and Ueno، نويسنده , , K and Chang، نويسنده , , Y.H and Wang، نويسنده , , C.H. and Hou، نويسنده , , W.S، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Abstract :
We measured the radiation damage on an optical glue called Eccobond-24, which is a candidate for CsI and BGO crystal calorimeters of the BELLE detector of the KEK B-factory. Absorption spectrophotometry in the range 300–800 nm was used to monitor the radiation damage. The maximum equivalent dose was 1.64 Mrad. The glue shows effects of damage, but is acceptable for the radiation level in the above-mentioned experiment.
Keywords :
Radiation hardness , Radiation damage , Glue , Epoxy , optical
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A