Title of article
Measurement of radiation damage on an epoxy-based optical glue
Author/Authors
Huang، نويسنده , , H.C and Peng، نويسنده , , K.C and Sahu، نويسنده , , S.K and Ueno، نويسنده , , K and Chang، نويسنده , , Y.H and Wang، نويسنده , , C.H. and Hou، نويسنده , , W.S، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
2
From page
559
To page
560
Abstract
We measured the radiation damage on an optical glue called Eccobond-24, which is a candidate for CsI and BGO crystal calorimeters of the BELLE detector of the KEK B-factory. Absorption spectrophotometry in the range 300–800 nm was used to monitor the radiation damage. The maximum equivalent dose was 1.64 Mrad. The glue shows effects of damage, but is acceptable for the radiation level in the above-mentioned experiment.
Keywords
Radiation hardness , Radiation damage , Glue , Epoxy , optical
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1997
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2174835
Link To Document