Title of article :
Cyclotron isochronism tuning by phase measurements with a fast scintillator at very low beam intensity
Author/Authors :
Boy، نويسنده , , L. and Bibet، نويسنده , , D. and Moscatello، نويسنده , , M.H. and Launé، نويسنده , , B. and Mueller، نويسنده , , A.C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
7
From page :
195
To page :
201
Abstract :
The goal of this full-scale experiment was to tune the cyclotron at very low-intensity (102 – 103 pps). A special low-intensity probe for phase measurements was built and tested in the GANIL SSC2 cyclotron. It is based on a fast plastic scintillator and mounted on a radial probe. Using this detector the phase extension and the central phase of the beam were measured and the cyclotron isochronism was accurately tuned.
Keywords :
Isochronism , cyclotron , Plastic scintillator , Phase measurements