• Title of article

    Performance of resistive plates counters operated with mixtures containing different freons

  • Author/Authors

    Arena، نويسنده , , V. and Boca، نويسنده , , G. and Bonomi، نويسنده , , G. and Gianini، نويسنده , , G. and Liguori، نويسنده , , G. and Merlo، نويسنده , , M. and Ratti، نويسنده , , S.P. and Riccardi، نويسنده , , C. and Viola، نويسنده , , L.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    9
  • From page
    156
  • To page
    164
  • Abstract
    We present the performance of Resistive Plates Counters filled with gas mixtures containing different freons. Efficiency, single rate, cluster size were measured and compared. In particular, the charge collected by single strips has been compared to that obtained with a mixture containing R13B1 freon no longer allowed in several countries. Preliminary results show that R116 seems to be a good replacement, leading to performance similar to that obtained using R13B1 freon.
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1997
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2176781