• Title of article

    Design and performance of the SLD vertex detector: a 307 Mpixel tracking system

  • Author/Authors

    Abe، نويسنده , , K. and Arodzero، نويسنده , , A and Baltay، نويسنده , , C and Brau، نويسنده , , J.E and Breidenbach، نويسنده , , M and Burrows، نويسنده , , P.N. and Chou، نويسنده , , A.S and Crawford، نويسنده , , G and Damerell، نويسنده , , C.J.S and Dervan، نويسنده , , P.J and Dong، نويسنده , , D.N and Emmet، نويسنده , , W and English، نويسنده , , R.L and Etzion، نويسنده , , E and Foss، نويسنده , , M and Frey، نويسنده , , R and Haller، نويسنده , , G and Hasuko، نويسنده , , K and Hertzbach، نويسنده , , S.S and Hoeflich، نويسنده , , J and Huffer، نويسنده , , M.E and Jackson، نويسنده , , D.J and Jaros، نويسنده , , J.A and Kelsey، نويسنده , , J and Lee، نويسنده , , I and Lia، نويسنده , , V and Lintern، نويسنده , , A.L. and Liu، نويسنده , , M.X and Manly، نويسنده , , S.L and Masuda، نويسنده , , H and McKemey، نويسنده , , A.K. and Moore، نويسنده , , T.B and Nichols، نويسنده , , A and Nagamine، نويسنده , , T and Oishi، نويسنده , , N and Osborne، نويسنده , , L.S and Russell، نويسنده , , J.J and Ross، نويسنده , , D and Serbo، نويسنده , , V.V and Sinev، نويسنده , , N.B and Sinnott، نويسنده , , J. and Skarpaas VIII، نويسنده , , K and Smy، نويسنده , , M.B and Snyder، نويسنده , , J.A and Strauss، نويسنده , , M.G and Dong، نويسنده , , Su and Suekane، نويسنده , , F and Taylor، نويسنده , , F.E and Trandafir، نويسنده , , A.I and Usher، نويسنده , , T and Verdier، نويسنده , , R and Watts، نويسنده , , S.J and Weiss، نويسنده , , E.R and Yashima، نويسنده , , J and Yuta، نويسنده , , H. and Zapalac، نويسنده , , G، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    57
  • From page
    287
  • To page
    343
  • Abstract
    This paper describes the design, construction, and initial operation of SLDʹs upgraded vertex detector which comprises 96 two-dimensional charge-coupled devices (CCDs) with a total of 307 Mpixel. Each pixel functions as an independent particle detecting element, providing space point measurements of charged particle tracks with a typical precision of 4 μm in each co-ordinate. The CCDs are arranged in three concentric cylinders just outside the beam-pipe which surrounds the e+e− collision point of the SLAC Linear Collider (SLC). The detector is a powerful tool for distinguishing displaced vertex tracks, produced by decay in flight of heavy flavour hadrons or tau leptons, from tracks produced at the primary event vertex. The requirements for this detector include a very low mass structure (to minimize multiple scattering) both for mechanical support and to provide signal paths for the CCDs; operation at low temperature with a high degree of mechanical stability; and high speed CCD readout, signal processing, and data sparsification. The lessons learned in achieving these goals should be useful for the construction of large arrays of CCDs or active pixel devices in the future in a number of areas of science and technology.
  • Keywords
    Tau lepton , Particle tracking , Vertex detector , Pixels , Charge-coupled device (CCD) Heavy flavour , Charm quark , Bottom quark
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1997
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number