Author/Authors :
Baru، نويسنده , , S.E and Blinov، نويسنده , , A.E and Blinov، نويسنده , , V.E and Groshev، نويسنده , , V.R and Kolachev، نويسنده , , G.M. and Kozlov، نويسنده , , V.N and Minakov، نويسنده , , G.D and Onuchin، نويسنده , , A.P and Petrosyan، نويسنده , , S.S and Rylin، نويسنده , , A.V and Savinov، نويسنده , , G.A and Shamov، نويسنده , , A.G and Shusharo، نويسنده , , A.I and Talyshev، نويسنده , , A.A and Yushkov، نويسنده , , A.N، نويسنده ,
Abstract :
The 1 m long and 1 m outer diameter chamber consists of 42 layers. The chamber is based on a cell of the jet type with drift distance of 30 mm. The measurements of the spatial resolution and the aging tests were performed with DME gas on prototypes. The resolution averaged over the drift distance has a value of 45 μm. The relative gain drop is equal to 45%/(C/cm). The design and construction of the chamber, the gas system, the laser calibration system and first results of the cosmic-ray test are discussed.