Title of article
The gain control system for the COPP (coincidence photon–proton) apparatus
Author/Authors
Capitani، نويسنده , , G.P. and Luxardo، نويسنده , , S. and Massone، نويسنده , , A.M. and Ottonello، نويسنده , , P. and Reolon، نويسنده , , A.R. and Sanzone، نويسنده , , M. and Zucchiatti، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
9
From page
166
To page
174
Abstract
We have built and operated a system which monitors and controls the response of the 12 lead-glass and the 12 plastic scintillator detectors in the COincidence Photon–Proton (COPP) apparatus. We present here the detailed operation of the system and its performances during the experiment’s runs. The gain control system, acting on the high-voltage values of the photomultiplier tubes, allows one to achieve a long term gain stability as good as 2% for each detector.
Keywords
PMT gain , Detector response stability , Gain control system