• Title of article

    Installation, calibration and application of incore miniature neutron detector in Tehran research reactor (TRR)

  • Author/Authors

    Khalafi، نويسنده , , H and Gharib، نويسنده , , M، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    5
  • From page
    374
  • To page
    378
  • Abstract
    Determination of peaking factor, normally requires wire-scanning or gold activation techniques. These techniques are rather awkward and slow. A more versatile technique based on miniature neutron detector (MND) is developed and used for Tehran research reactor.
  • Keywords
    Miniature neutron detector , Neutron flux measurements , Peaking factor , research reactor
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    1998
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number