Title of article :
Stability of a line receiver (0–T) preamplifier, connected to a capacitive detector via a transmission line
Author/Authors :
Battistoni، نويسنده , , G and Camin، نويسنده , , D.V. and Fedyakin، نويسنده , , N and Ramaioli، نويسنده , , P and Shuvalov، نويسنده , , R، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
12
From page :
533
To page :
544
Abstract :
We analyze the stability of a line receiver (0–T) preamplifier proposed to readout the ionization signal of the ATLAS LAr electromagnetic calorimeter. The transport of detector signal to the preamplifier input via a cable is analyzed on the basis of classical theory of wave propagation in transmission lines. It is shown that the analysis of stability can be reduced to the examination of zeros of the expression Zin+ZDC , where Zin is the input impedance of the 0–T and ZDC is the impedance of the detector plus cable, as seen by the preamplifier. An experimental method to measure the preamplifier input impedance in a range 1–200 MHz is described. The stability function Zin+ZDC was built by using the combination of experimental data (Zin) and calculations (ZDC) and was used to analyze the stability of two versions of 0–T preamplifier at different experimental conditions. It is illustrated that if the vector end of this semiempirical stability function makes a clockwise encirclement of zero, then the preamplifier is definitely unstable.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1999
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2180759
Link To Document :
بازگشت