Title of article
A warm-liquid calorimeter for cosmic-ray hadrons
Author/Authors
Engler، نويسنده , , J. A. Fessler، نويسنده , , F. and Hِrandel، نويسنده , , J.R. and Holst، نويسنده , , and T. A. Keim، نويسنده , , H. and Mathes، نويسنده , , H.J. and Mielke، نويسنده , , H.H. and Milke، نويسنده , , J. and Raidt، نويسنده , , U. and Wochele، نويسنده , , J.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
15
From page
528
To page
542
Abstract
An iron sampling calorimeter for cosmic-ray hadrons used in the centre of a large air shower experiment is described. The iron absorber is interspersed with eight layers of ionisation chambers filled with the room-temperature liquids tetramethylsilane and tetramethylpentane. Experiences gained from the calorimeter, its performance and long-term stability are presented. For energies in the TeV range shower profiles and transition curves have been measured and are compared with Monte Carlo calculations employing the FLUKA code. Good agreement has been found except in the lateral halo region. In the outer regions the energy deposition found is smaller than that obtained by the simulations.
Keywords
Hadronic shower simulation , TMP calorimeter , Liquid ionisation chambers , Hadron sampling calorimeter , Cosmic-ray hadrons , TMS calorimeter
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
1999
Journal title
Nuclear Instruments and Methods in Physics Research Section A