Title of article :
Portable γ- and X-ray analyzers based on CdTe p–i–n detectors
Author/Authors :
Khusainov، نويسنده , , A.K. and Antonova، نويسنده , , T.A. and Bahlanov، نويسنده , , S.V. and Derbin، نويسنده , , A.V. and Ivanov، نويسنده , , V.V. and Lysenko، نويسنده , , V.V. and Morozov، نويسنده , , F. and Mouratov، نويسنده , , V.G. and Muratova، نويسنده , , V.N. and Petukhov، نويسنده , , Y.A. and Pirogov، نويسنده , , A.M. and Polytsia، نويسنده , , O.P. and Saveliev، نويسنده , , V.D. and Solovei، نويسنده , , V.A. an، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
9
From page :
223
To page :
231
Abstract :
Several portable instruments are designed using previously reported CdTe detector technology. These can be divided into three groups according to their energy ranges: (1) 3–30 keV XRF analyzers, (2) 5–120 keV wide range XRF analyzers and (3) γ-ray spectrometers for operation up to 1500 keV. These instruments are used to inspect several hundreds of samples in situ during a working day in applications such as a metal alloy verification at customs control. Heavy metals are identified through a 3–100 mm thick package with these instruments. Surface contamination by heavy metals (for example toxins such as Hg, Th and Pb in housing environmental control), the determination of Pb concentration in gasoline, geophysical control in mining, or nuclear material control are other applications. The weight of these XRF probes is about 1 kg and two electronic designs are used: one with embedded computer and another based on a standard portable PC. The instruments have good precision and high productivity for measurements in situ. The detection limit of Ce is about 0.03% when measured in the presence of 10% barium for 15 s. The detection limit when measuring K-shell X-ray of heavy metals contamination is about 0.1 mg/cm2 for 15 s. Two types of probes for γ-spectrometry with small and large (>30 mm 3) detector volumes provide both high- and low-activity of nuclear fuel analysis. The maximum distance between the probes and electronics unit is 20 m. The γ-spectrometers are equipped with electronics to correct signal distortion due to slow carrier effects. This allows the instrument to achieve an energy resolution of about 2.5 keV at 662 keV. Several modes to process spectra are possible including semiquantitative and total real-shape fitting.
Keywords :
?-spectrometry , Portable XRF instruments , Read-through analysis , Customs control , Semiconductor detectors , IAEA inspection
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
1999
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2181400
Link To Document :
بازگشت