Title of article :
Forward-bias operation of Si detectors:: a way to work in high-radiation environment
Author/Authors :
Beattie، نويسنده , , L.J. and Chilingarov، نويسنده , , A. and Sloan، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
10
From page :
293
To page :
302
Abstract :
Test diodes irradiated by neutrons with fluences up to 1015 cm−2 were successfully operated as particle detectors under forward bias. Charge Collection Efficiency (CCE) of ∼70% was reached for minimum ionising particles at relatively low-bias voltages. The more usual reverse bias requires ∼10 times larger voltage to give a similar CCE. A decrease in the charge trapping is observed in forward bias operation compared to that under reverse bias. The dark current under forward bias has the usual temperature dependence. This could be used to optimise the operation condition of forward-biased detectors in a real experiment.
Keywords :
Irradiated silicon detectors , Forward bias operation
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2000
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2184379
Link To Document :
بازگشت