Title of article
Diagnostics for the 5 MeV electron cooling system
Author/Authors
Nagaitsev، نويسنده , , Sergei and Saewert، نويسنده , , Greg and Shemyakin، نويسنده , , Alexander and Warner، نويسنده , , Arden، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
9
From page
246
To page
254
Abstract
A prototype of a novel electron cooling system that will operate in the MeV energy range is now being built at Fermilab. This system will have very stringent beam optics requirements. To meet these requirements, beam diagnostics that allow measuring a beam position to 50 μm in 1 Hz BW and a beam diameter to 0.1 mm out of 1 cm needs to be developed. In this paper we describe various possible diagnostics, discuss their limitations and preliminary test results.
Keywords
Accelerator , electron beam , electron cooling , Beam diagnostics
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2000
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2184949
Link To Document