Title of article
Peak-sensing discriminator for multichannel detectors with cross-talk
Author/Authors
Gorin، نويسنده , , A and Kuznetsov، نويسنده , , A and Manuilov، نويسنده , , I and Riazantsev، نويسنده , , A and Sidorov، نويسنده , , A and Kobayashi، نويسنده , , M and Kuroda، نويسنده , , K and Okada، نويسنده , , K and Takeutchi، نويسنده , , F، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
9
From page
280
To page
288
Abstract
In view of handling the anode signals from the position-sensitive photomultiplier a new front-end electronic circuit has been designed and realized, which allows one to suppress annoying effects of the cross-talk between adjacent channels. The circuit was tested in association with a scintillating fibre detector in a test beam at CERN. The basic performances, such as the detection efficiency and its uniformity, as well as the hit multiplicity for single tracks were compared to those of the conventional electronics based on the simple threshold discriminators. A great advantage of the peak-sensing circuit was experimentally demonstrated, in particular, in its real-time digitization of the track position without significant ambiguity of the track position due to the cross-talk.
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2000
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2187488
Link To Document