Title of article :
Multi-electrode CZT detector packaging using polymer flip chip bonding
Author/Authors :
Jordanov، نويسنده , , Valentin T. and Macri، نويسنده , , John R. and Clayton، نويسنده , , James E. and Larson، نويسنده , , Kipp A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
Polymer flip chip bonding has been used to package a multi-electrode CZT detector. During the packaging process the temperature of all components was kept less than 80°C. The size of the conductive epoxy eontacts is less than 120 μm in diameter. Thermal cycling, and random and structural vibration tests indicate reliable detector–substrate interconnection and rugged construction.
Keywords :
Epoxy bonding , CZT detectors , Flip-Chip bonding , Detector packaging
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A