Title of article
Study of the compensated lead hadron calorimeter on hadron, electron and lead–ion beams
Author/Authors
Alekseev، نويسنده , , G.A. and Apokin، نويسنده , , V.D. and Buyanov، نويسنده , , O.V. and Chuiko، نويسنده , , B.V. and Grishin، نويسنده , , V.N. and Katchanov، نويسنده , , V.A. and Khodyrev، نويسنده , , V.Yu. and Medvedev، نويسنده , , V.A. and Minaev، نويسنده , , N.G. and Mochalov، نويسنده , , V.V. and Rykalin، نويسنده , , V.V. and Semenov، نويسنده , , P.A. and Solovianov، نويسنده , , V.L. and Stepushkin، نويسنده , , S.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
3
From page
381
To page
383
Abstract
The results of tests on a compensated lead hadron calorimeter with cell size 10×10 cm2, thickness 8 nuclear interaction lengths and sampling of 16 mm lead, 4 mm scintillator, with hadron, electron and lead–ion beams up to 32 TeV total energy are presented. The hadronic energy resolution of the calorimeter is 57%/E, the nonuniformity is better than 10% and the measured ratio e/h=1.01. Five hundred cells of this calorimeter have been made for experiments at CERN and IHEP, Protvino.
Keywords
Compensated lead hadron calorimeter
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2001
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2189624