Title of article :
X-ray microtome by fluorescence tomography
Author/Authors :
Simionovici، نويسنده , , A. and Chukalina، نويسنده , , M. and Günzler، نويسنده , , F. and Schroer، نويسنده , , Ch. and Snigirev، نويسنده , , A. and Snigireva، نويسنده , , I. and Tümmler، نويسنده , , J. and Weitkamp، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
4
From page :
889
To page :
892
Abstract :
The X-ray fluorescence microtomography method is presented, which is capable of virtually slicing samples to obtain cross-sections of their inner structure. High precision experimental results of fluo-tomography in “pencil-beam” geometry with up to 1.2 μm resolution are described. Image reconstructions are based on either a simplified algebraic reconstruction method (ART) or the filtered back-projection method (FBP). Phantoms of inhomogenous test objects as well as biological samples are successfully analyzed.
Keywords :
X-ray fluorescence tomography , Synchrotron radiation
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2001
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2192162
Link To Document :
بازگشت