• Title of article

    Monte carlo feasibility study of an active neutron assay technique for full-volume UF6 cylinder assay using a correlated interrogation source

  • Author/Authors

    Miller، نويسنده , , Karen A. and Menlove، نويسنده , , Howard O. and Swinhoe، نويسنده , , Martyn T. and Marlow، نويسنده , , Johnna B.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    152
  • To page
    157
  • Abstract
    Uranium cylinder assay plays an important role in the nuclear material accounting at gas centrifuge enrichment plants. The Passive Neutron Enrichment Meter (PNEM) was designed to determine uranium mass and enrichment in 30B and 48Y cylinders using total neutron and coincidence counting in the passive mode. 30B and 48Y cylinders are used to hold bulk UF6 feed, product, and tails at enrichment plants. In this paper, we report the results of a Monte-Carlo-based feasibility study for an active uranium cylinder assay system based on the PNEM design. There are many advantages of the active technique such as a shortened count time and a more direct measure of 235U content. The active system is based on a modified PNEM design and uses a 252Cf source as the correlated, active interrogation source. We show through comparison with a random AmLi source of equal strength how the use of a correlated driver significantly boosts the active signal and reduces the statistical uncertainty. We also discuss ways in which an active uranium cylinder assay system can be optimized to minimize background from 238U fast-neutron induced fission and direct counts from the interrogation source.
  • Keywords
    Monte Carlo , uranium hexafluoride , Active interrogation , Nuclear safeguards , Uranium enrichment
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2013
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number