• Title of article

    Improved modeling of microchannel plate response to hard X-rays

  • Author/Authors

    Farley، نويسنده , , D.R. and Izumi، نويسنده , , N. and Landen، نويسنده , , O.L.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    7
  • From page
    17
  • To page
    23
  • Abstract
    An improved model for microchannel platequantum efficiency and response at higher X-ray energies (up to 100ʹs keV) is described, which builds on previous models by incorporating a more detailed consideration of photoelectron energies released in the MCP bulk. The contribution of multiple channel walls is included in the total response calculation. This model shows that MCP quantum efficiency and response decay as power law functions with energy, for photon energies>140 keV.
  • Keywords
    Quantum efficiency , Response , Microchannel plate , X-Ray
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2013
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number