Title of article :
The calorimeter project for the Mu2e experiment
Author/Authors :
Budagov، نويسنده , , J. and Carosi، نويسنده , , R. and Cervelli، نويسنده , , F. P. Cheng، نويسنده , , C. and Cordelli، نويسنده , , M. and Davydov، نويسنده , , Yu. and Downie، نويسنده , , E.J. and Echenard، نويسنده , , B. and Giovannella، نويسنده , , S. and Glagolev، نويسنده , , V. and Happacher، نويسنده , , F. and Hitlin، نويسنده , , D. and Luca، نويسنده , , A. and Miscetti، نويسنده , , S. and Ongmonkolkul، نويسنده , , P. and Onorato، نويسنده , , G. and Otte، نويسنده , , P. and Pezzullo، نويسنده , , G. and Pileggi، نويسنده , , Strashimir G. and Porter، نويسنده , , F. and Saputi، نويسنده , , A. DI SARRA، نويسنده , , I. and Tassielli، نويسنده , , G. and Thomas، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
4
From page :
56
To page :
59
Abstract :
The Mu2e experiment at Fermilab aims to measure the charged lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the rest mass of the muon (104.97 MeV). We expect to set a limit of ∼ 6×10 − 17 at 90% CL in three years of running, using an intense and clean pulsed μ − beam providing ∼ 10 18 stopped muons on target in three years of running. The experiment performs a strong suppression of potential background by gating off the prompts and performing precise momentum determination in conjunction with an highly efficient cosmic veto. The calorimeter should confirm that the candidates reconstructed by the tracker system are indeed conversion electrons and provide an independent trigger (or event reduction filter) for the experiment. It should also provide standalone muon to electron rejection. Moreover, it must be able to keep functionality in a high radiation dose environment inside a 10 − 4 torr vacuum enclosure and in a presence of 1 T axial magnetic field. In order to accomplish all these tasks, a LYSO crystals calorimeter has been chosen. We show the proposed design and the experimental results obtained by exposing a small size calorimeter prototype to a tagged photon beam from 40 to 300 MeV at the A2 photon facility of the Mainz Microton (MAMI), Germany.
Keywords :
Calorimetry , LYSO crystals , Mu2e experiment
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2013
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2194108
Link To Document :
بازگشت