Abstract :
A simple, efficient, and robust on-line data-processing scheme was developed for the digital front-end electronics of the electromagnetic calorimeter of the PANDA spectrometer at FAIR, Darmstadt. The implementation of the processing algorithm in FPGA enables the construction of an almost dead-time free data acquisition system. The prototype of a complete trigger-less readout chain has been developed and evaluated. The precision of time synchronisation commands has been verified. A pile-up recovery algorithm was developed and evaluated over a large dynamic range of signal amplitudes.
Keywords :
Electromagnetic calorimeter , Sampling ADC , Digital filtering , feature extraction , Pile-up recovery , Trigger-less readout