• Title of article

    Discharge studies and prevention in the gas electron multiplier (GEM)

  • Author/Authors

    Bachmann، نويسنده , , S. and Bressan، نويسنده , , A. and Capeلns، نويسنده , , M. and Deutel، نويسنده , , M. and Kappler، نويسنده , , S. and Ketzer، نويسنده , , B. and Polouektov، نويسنده , , A. and Ropelewski، نويسنده , , L. and Sauli، نويسنده , , F. and Schulte، نويسنده , , E. and Shekhtman، نويسنده , , L. and Sokolov، نويسنده , , A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    15
  • From page
    294
  • To page
    308
  • Abstract
    The gas electron multiplier (GEM) used as single proportional counter or in a cascade of two or more elements, permits to attain high gains and to perform detection and localization of ionizing tracks at very high radiation rates. As in other micro-pattern detectors, however, the occasional occurrence of heavily ionizing trails may trigger a local breakdown, with possible harmful consequences on the device itself and on the readout electronics. This paper describes a systematic investigation of the discharge mechanisms in single and multiple GEM structures, and suggests various strategies to reduce both the energy and the probability of the discharges.
  • Keywords
    Gas discharges , High rate radiation detector , Streamer , Gas electron multiplier , GEM
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2002
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number