Title of article :
Feynman-α technique for measurement of detector dead time using a 30 kW tank-in-pool research reactor
Author/Authors :
Akaho، نويسنده , , E.H.K. and Intsiful، نويسنده , , J.D.K. and Maakuu، نويسنده , , B.T. and Anim-Sampong، نويسنده , , S. and Nyarko، نويسنده , , B.J.B.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
Reactor noise analysis was carried out for Ghana Research Reactor-1 GHARR-1, a tank-in-pool type reactor using the Feynman-α technique (variance-to-mean method). Measurements made at different detector positions and under subcritical conditions showed that the technique could not be used to determine the prompt decay constant for the reactor which is Be reflected with photo-neutron background. However, for very low dwell times the technique was used to measure the dead time of the detector which compares favourably with the value obtained using the α-conventional method.
Keywords :
Feynman-? technique , Reactor noise analysis , Detector dead time , Dwell time
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A