Title of article :
Testbeam and laboratory test results of irradiated 3D CMS pixel detectors
Author/Authors :
Bubna، نويسنده , , Mayur and Alagoz، نويسنده , , Enver and Cervantes، نويسنده , , Mayra and Krzywda، نويسنده , , Alex and Arndt، نويسنده , , Kirk and Obertino، نويسنده , , Margherita and Solano، نويسنده , , Ada and Dalla Betta، نويسنده , , Gian-Franco and Menace، نويسنده , , Dario and Moroni، نويسنده , , Luigi and Uplegger، نويسنده , , Lorenzo and Rivera، نويسنده , , Ryan and Osipenkov، نويسنده , , Ilya and Andresen، نويسنده , , Jeff and Bolla، نويسنده , , Gino and Bortoletto، نويسنده , , Daniela and Boscardin، نويسنده , , Maurizio and Marie Brom، نويسنده , , Jean and Brosius، نويسنده , , Richard and Chramowicz، نويسنده , , John and Cumalat، نويسنده , , John and Dinardo، نويسنده , , Mauro and Dini، نويسنده , , Paolo and Jensen، نويسنده , , Frank and Kumar، نويسنده , , Ashish and Kwan، نويسنده , , Simon and Lei، نويسنده , , C.M. and Povoli، نويسنده , , Marco and Prosser، نويسنده , , Alan and Ngadiuba، نويسنده , , Jennifer and Perera، نويسنده , , Lalith and Shipsey، نويسنده , , Ian and Tan، نويسنده , , Ping and Tentindo، نويسنده , , Silvia and Terzo، نويسنده , , Stefano and Tran، نويسنده , , Nhan and Wagner، نويسنده , , Stephen R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
5
From page :
52
To page :
56
Abstract :
The CMS silicon pixel detector is the tracking device closest to the LHC p–p collisions, which precisely reconstructs the charged particle trajectories. The planar technology used in the current innermost layer of the pixel detector will reach the design limit for radiation hardness at the end of Phase I upgrade and will need to be replaced before the Phase II upgrade in 2020. Due to its unprecedented performance in harsh radiation environments, 3D silicon technology is under consideration as a possible replacement of planar technology for the High Luminosity-LHC or HL-LHC. 3D silicon detectors are fabricated by the Deep Reactive-Ion-Etching (DRIE) technique which allows p- and n-type electrodes to be processed through the silicon substrate as opposed to being implanted through the silicon surface. The 3D CMS pixel devices presented in this paper were processed at FBK. They were bump bonded to the current CMS pixel readout chip, tested in the laboratory, and testbeams carried out at FNAL with the proton beam of 120 GeV/c. In this paper we present the laboratory and beam test results for the irradiated 3D CMS pixel devices.
Keywords :
CMS pixel detector , Radiation hardness , 3D technology , LHC upgrade
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2013
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2195037
Link To Document :
بازگشت