Title of article
Evaluation of the Timepix chip radiation hardness using a 60Co source
Author/Authors
?arn?، نويسنده , , M?ria and Du?evov?، نويسنده , , Kate?ina and Hejtm?nek، نويسنده , , Martin and Kon?ek، نويسنده , , Ond?ej and Mar?i?ovsk?، نويسنده , , Michal، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
5
From page
501
To page
505
Abstract
Radiation damage is a widely studied topic for its effects on detectors and supporting electronics in various practical applications. Radiation hardness and stability of the detector properties are critical parameters in applications of semiconductor radiation detectors. The 0.25 μ m CMOS technology used in fabrication of the Medipix2 and Timepix chips provides high degree of inherent radiation hardness. We present the study of operational, detection and signal processing properties of the irradiated Timepix chip exposed to a high-flux 60Co source reaching the operational limits of the chip.
Keywords
Radiation hardness , Medipix , Pixel detector
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2013
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2195214
Link To Document