Title of article :
Pulse shape analysis of a two fold clover detector with an EMD based new algorithm: A comparison
Author/Authors :
Meenakshi and Siwal، نويسنده , , Davinder and Mandal، نويسنده , , Pinaki S. and Palit، نويسنده , , R. K. Sethi، نويسنده , , J. and Garg، نويسنده , , R. and Saha، نويسنده , , S. and Prasad، نويسنده , , Awadhesh and Chavan، نويسنده , , P.B. and Naidu، نويسنده , , B.S. and Jadhav، نويسنده , , S. and Donthi، نويسنده , , R. and Schaffner، نويسنده , , H. and Adamczewski-Musch، نويسنده , , J. and Kurz، نويسنده , , N. and Wollersheim، نويسنده , , H.J. and Singh، نويسنده , , R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
9
From page :
108
To page :
116
Abstract :
An investigation of Empirical Mode Decomposition (EMD) based noise filtering algorithm has been carried out on a mirror signal from a two fold germanium clover detector. EMD technique can decompose linear as well as nonlinear and chaotic signals with a precise frequency resolution. It allows to decompose the preamplifier signal (charge pulse) on an event-by-event basis. The filtering algorithm provides the information about the Intrinsic Mode Functions (IMFs) mainly dominated by the noise. It preserves the signal information and separates the overriding noise oscillations from the signals. The identification of noise structure is based on the frequency distributions of different IMFs. The preamplifier noise components which distort the azimuthal co-ordinates information have been extracted on the basis of the correlation between the different IMFs and the mirror signal. The correlation studies have been carried out both in frequency and time domain. The extracted correlation coefficient provides an important information regarding the pulse shape of the γ-ray interaction in the detector. A comparison between the EMD based and state-of-the-art wavelet based denoising techniques has also been made and discussed. It has been observed that the fractional noise strength distribution varies with the position of the collimated gamma-ray source. Above trend has been reproduced by both the denoising techniques.
Keywords :
Segmented germanium detector , Pulse shape analysis , Empirical mode decomposition (EMD) , Fast Fourier transform (FFT)
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2014
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2195819
Link To Document :
بازگشت