Title of article :
Absolute efficiency measurements with the 10B based Jalousie detector
Author/Authors :
Modzel، نويسنده , , G. and Henske، نويسنده , , M. and Houben، نويسنده , , A. and Klein، نويسنده , , M. and Kِhli، نويسنده , , M. and Lennert، نويسنده , , P. and Meven، نويسنده , , M. and Schmidt، نويسنده , , C.J. Band-Schmidt، نويسنده , , U. and Schweika، نويسنده , , W.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
6
From page :
90
To page :
95
Abstract :
The 10B based Jalousie detector is a replacement for 3He counter tubes, which are nowadays less affordable for large area detectors due to the 3He crisis. In this paper we investigate and verify the performance of the new 10B based detector concept and its adoption for the POWTEX diffractometer, which is designed for the detection of thermal neutrons with predicted detection efficiencies of 75–50% for neutron energies of 10–100 meV, respectively. The predicted detection efficiency has been verified by absolute measurements using neutrons with a wavelength of 1.17 Å (59 meV).
Keywords :
Jalousie , 10-Boron , 3-He alternative , neutron detector , POWTEX , Neutron diffraction
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2014
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2195913
Link To Document :
بازگشت