Title of article :
The performance and long term stability of the D0 Run II forward muon scintillation counters
Author/Authors :
Bezzubov، نويسنده , , V. and Denisov، نويسنده , , D. and Evdokimov، نويسنده , , V. and Lipaev، نويسنده , , Darya V. and Shchukin، نويسنده , , A. and Vasilyev، نويسنده , , I.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Abstract :
The performance of the D0 experiment forward muon scintillation counters system during Run II of the Tevatron from 2001 to 2011 is described. The system consists of 4214 scintillation counters in six layers. The long term stability of the counters amplitude response determined using LED calibration system and muons produced in proton–antiproton collisions is presented. The averaged signal amplitude for counters of all layers has gradually decreased over ten years by 11%. The reference timing, determined using LED calibration, was stable within 0.26 ns. Averaged value of muon timing peak position was used for periodic D0 clock signal adjustments to compensate seasonal drift caused by temperature variations. Counters occupancy for different triggers in physics data collection runs and for minimum bias triggers are presented. The single muon yields versus time and the luminosity dependence of yields were stable for the forward muon system within 1% over 10 years.
Keywords :
Scintillation counters , Muon system , Monitoring , D0 experiment
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A