• Title of article

    Study on GASTOF – A 10 ps resolution timing detector

  • Author/Authors

    Bonnet، نويسنده , , Luc and Liao، نويسنده , , Junhui and Piotrzkowski، نويسنده , , Krzysztof، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2014
  • Pages
    8
  • From page
    77
  • To page
    84
  • Abstract
    GASTOF (Gas Time Of Flight) is a type of fast-time detector affiliated to the HPS (High Precision Spectrometer) project which is a forward physics collaborator within CMS. It is a picosecond time resolution Cherenkov gas detector using very fast single anode micro-channel plate photomultiplier (Hamamatsu R3809U-50 or Photek 210) as a photon detector. We firstly measured characteristics of these two types of MCP-PMTs by a fast laser pulse in lab. Then two GASTOF detectors both equipped with a Hamamatsu R3809U-50 tube were studied in a beam test at CERN. According to the analysis of beam test data, the average number of photoelectrons (phe) was 2.0 for both phototubes. By making a cut on the number of photoelectrons such that the mean phe was 3.6 in one phototube and 3.2 in another, we obtained a time resolution of σ ~ 11.7 picosecond (ps) and σ ~ 8.2 ps .
  • Keywords
    GASTOF , Cherenkov gas detector , ps time resolution , 10  , MCP-PMTs