Title of article :
Simulation of light collection in the CMS lead tungstate crystals with the program Litrani: coating and surface effects
Author/Authors :
Chipaux، نويسنده , , R and Gentit، نويسنده , , F.-X، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
7
From page :
48
To page :
54
Abstract :
The accuracy of the lead tungstate electromagnetic calorimeter of the CMS experiment under construction at CERN relies, among other things, on the correction of the calibration parameter from variations due to crystal ageing. This ageing will be measured by a so-called monitoring system, but the relation between monitoring and calibration parameter variations is not so trivial, and depends much on the overall optical characteristics of crystal and photodetector. We present here simulations done with the program Litrani based on real ageing data for a realistic CMS crystal with a defined surface quality (optically polished, with or without one lateral face slightly depolished), covered by coatings of various characteristics, from totally absorbing to nominal aluminum or diffusing medium. The correlation coefficient between monitoring and scintillation signals depends greatly on these characteristics, and varies between about 1.3 and more than 10 (the optimum being one).
Keywords :
Scintillator detector , ageing , Light yield , Ray tracing
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2002
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2196515
Link To Document :
بازگشت