Title of article
The biological shield of a high-intensity spallation source: a Monte Carlo design study
Author/Authors
Koprivnikar، نويسنده , , M. and Schachinger، نويسنده , , E، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
14
From page
571
To page
584
Abstract
The design of high-intensity spallation sources requires best possible estimates for the biological shield. We discuss the layout of the target station shield using Monte Carlo simulation techniques. In order to achieve reasonable computing times together with acceptable accuracy biasing techniques are to be employed and it is the main purpose of this study to develop a calculational strategy for a 3D Monte Carlo simulation in effective shielding design. Two transport codes, MCNPX and FLUKA, are then applied to the same model spallation source (the European Spallation Source) and the results are compared.
Keywords
Spallation source shielding , Monte Carlo , Particle transport
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2002
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2196990
Link To Document