Cervelli، نويسنده , , F. and Chen، نويسنده , , G. and Coignet، نويسنده , , G. and Di Falco، نويسنده , , S. and Falchini، نويسنده , , E. and Lomtadze، نويسنده , , T. and Liu، نويسنده , , Z. and Maestro، نويسنده , , P. and Marrocchesi، نويسنده , , P.S. and Paoletti، نويسنده , , R. and Pilo، نويسنده , , F. and Turini، نويسنده , , N. and Valle، نويسنده , , G. and Vannini، نويسنده , , C. and Venanzoni، نويسنده , , G. and Yu، نويسنده , , Z.، نويسنده ,
Abstract :
A reduced scale prototype of the Pb–SciFi sampling e.m. calorimeter for the AMS-02 experiment was tested at CERN SPS beam line X5 at energies from 5 to 250 GeV. The detector was equalized with minimum ionizing particles and calibrated with electron beams. Effective sampling thickness, linearity and energy resolution were measured.