Title of article
Investigations and corrections of the light output uniformity of CsI(Tl) crystals
Author/Authors
van Goethem، نويسنده , , M.-J and Wallace، نويسنده , , M.S and Nett، نويسنده , , B.E and Famiano، نويسنده , , M.A and Herner، نويسنده , , K.R and Oostdyk، نويسنده , , D.J and Mocko، نويسنده , , M and Lynch، نويسنده , , W.G and Tsang، نويسنده , , M.B and Schotanus، نويسنده , , P and Telfer، نويسنده , , J and Clark، نويسنده , , H.L and Moroni، نويسنده , , A and de Souza، نويسنده , , R and Sobotka، نويسنده , , L.G، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
22
From page
455
To page
476
Abstract
The dependencies of the light output response of CsI(Tl) crystals for various charged particle beams are investigated. Measurements were performed using 5.5 MeV 241Am alpha particles, 220 MeV alpha and 110 MeV deuteron beams from the K500 Cyclotron at Texas A&M University, and p, 2H, 3He, 6Li, and 7Be beams from the Coupled Cyclotron Facility at Michigan State University. These measurements reveal a clear correlation between the non-uniformities observed in the same crystal for the various beams. Particle dependent global corrections were applied, resulting in final light output uniformities of the order of 0.1%. Annealed and non-annealed CsI(Tl) detectors and crystals with different thalium dopings are compared to determine whether annealing reduces the local variations in the light output. No significant correlation with the crystal fabrication process is observed.
Keywords
Scintillators—light output , CsI(Tl) detectors , RESOLUTION , Scintillator non-uniformity
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2004
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2198280
Link To Document