• Title of article

    Determination of a source in a box with two detectors. The general case

  • Author/Authors

    Presler، نويسنده , , O. and German، نويسنده , , U. and Golan، نويسنده , , H. and Alfassi، نويسنده , , Z.B.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    16
  • From page
    632
  • To page
    647
  • Abstract
    The study on using two detectors in order to measure accurately the activity of an unknown radioactive point source in a large bulky sample, named “a box”, was expanded to the general case, including the geometrical and absorption effects together. Two NaI(Tl) detectors were positioned at the opposite sides of the sample, and mathematical correlations of the count rates were used to develop an algorithm, which gave quantities independent on the source location. The mathematical algorithm was validated by experimental results. This method reduces to a great extent the uncertainty of the activity determination.
  • Keywords
    point source , General case , ABSORPTION , Geometry , dependence , location
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2004
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2198327