Title of article
Neutron irradiation field produced by 25 MeV deuterons bombarding on thick beryllium target for radiobiological study
Author/Authors
Takada، نويسنده , , Masashi and Mihara، نويسنده , , Erika and Nakamura، نويسنده , , Takashi and Honma، نويسنده , , Toshihiko and Kono، نويسنده , , Koji and Fujitaka، نويسنده , , Kazunobu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
11
From page
765
To page
775
Abstract
A fast neutron irradiation field for biological studies was established at the cyclotron facility in the National Institute of Radiological Sciences. Neutron spatial distributions and absorbed dose distributions were measured to characterize the neutron field. By using a simple technique that an aluminum plate activated by neutrons was exposed to the imaging plates, the width of the neutron-irradiated area was measured to be 23.6 cm with 2.5 mm spatial resolution. The absorbed dose distributions of neutrons and γ rays were obtained separately by using a tissue-equivalent plastic- and a graphite-walled low-pressure proportional counter. The neutron absorbed dose in a tissue-equivalent plastic was measured to be 144.6 (Gy/C). It was confirmed that this neutron field has only 1.8% contamination of γ -ray dose and has good quality for neutron irradiation to biological samples.
Keywords
Imaging plate , Biological study , Spatial distribution , Gamma Ray , Absorbed Dose , Neutron , TEPC
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2005
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2199046
Link To Document