• Title of article

    Backsplash testbeam results for the SPD subdetector of LHCb

  • Author/Authors

    Aguilَ، نويسنده , , E. and Ballabriga، نويسنده , , R. Wolfler Calvo، نويسنده , , M. and Garrido، نويسنده , , L. and Gascَn-Moreno، نويسنده , , D. and Graciani، نويسنده , , R. and Graugés، نويسنده , , E. L. Peralta، نويسنده , , D. and Vilasيs، نويسنده , , X. and Xirgu، نويسنده , , X.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    10
  • From page
    438
  • To page
    447
  • Abstract
    The Scintillator Pad Detector (SPD) of the LHCb experiment [1] is positioned just before the preshower subdetector (PS), in front of the electromagnetic calorimeter (ECAL). It has been designed to complete the calorimeter information performing an e / γ identification for the experiment level-0 trigger system. Backscattered particles produced in the PS and the ECAL might introduce inefficiencies in the e / γ separation performed by the SPD. A testbeam with electrons and pions, at different energies, has allowed an experimental study of this effect.
  • Keywords
    SPD , scintillator , Testbeam , LHCB , Backsplash , Calorimeter
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2005
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2199067