• Title of article

    Effect of temperature variation and gas composition on the stability of the RPC operation

  • Author/Authors

    ?wiok، نويسنده , , M. and Dominik، نويسنده , , W. and G?rski، نويسنده , , Laura M. and Krolikowski، نويسنده , , J.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    6
  • From page
    38
  • To page
    43
  • Abstract
    An Inverted Double Gap Resistive Plate Chambers (RPC) made of bakelite of 5×109 Ωcm volume resistivity was tested at avalanche rates up to 1 kHz/cm2/gap in the Gamma Irradiation Facility at CERN in 2001. The inner surfaces of the chamber electrodes were cladded using linseed oil varnish. Dependence of the intrinsic RPC noise and the stability of the gas gain on the gas temperature and the gas composition are discussed.
  • Keywords
    Ionisation detectors , Gas gain , RPC , SF6
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2003
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number