Title of article :
Performance of the readout system for MONOLITH
Author/Authors :
Candela، نويسنده , , A. and De Deo، نويسنده , , M. and DʹIncecco، نويسنده , , M. and Gustavino، نويسنده , , C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
5
From page :
194
To page :
198
Abstract :
In this paper, we describe the performance of the readout system for MONOLITH developed at the LNGS. This system is based on the use of flat cables as readout elements, instead of the conventional copper strips. The advantages of flat cable strips are the good performance, the easy installation and the possibility to realize complex readout systems. The X-coordinate readout system (X-system) is composed by 15 m long, Flat Cable Strips (FCS). The distribution of the time difference between the streamer signals transmitted at both the ends of the X-system FCS has a sigma resolution of the order of 100 ps. This resolution allows the measurement of the particle direction by means of the time-of-flight technique and can be exploited to measure the Y-coordinate with a resolution in the order of 1 cm. The Y-coordinate system is composed by short FCS connected together by a flat cable acting as a bus line. It allows the installation of the electronics outside the apparatus minimizing the number of channels.
Keywords :
monolith , Flat cable , RPC , Readout strip