• Title of article

    Optimisation of fast-neutron radiography by using a new imaging quality concept

  • Author/Authors

    van der Hagen، نويسنده , , T.H.J.J. and de Haan، نويسنده , , V.O. and de Leege، نويسنده , , P.F.A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    5
  • From page
    264
  • To page
    268
  • Abstract
    A new method is proposed for the quality assessment of a neutron radiographic image. The quality of visualisation can be expressed as a Figure of Merit (FOM) defined as the image contrast in terms of the statistical uncertainty. The FOM enables optimisation of the image contrast of the object under investigation by changing the instrument or object characteristics. The FOM is used to investigate the influence of background countrate due to unwanted events or scattered neutrons by both analytical calculations and Monte-Carlo simulations.
  • Keywords
    Figure of merit , Fast-neutron radiography , Quality assessment , Optimisation
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2004
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2200976