Title of article :
An experimentally robust technique for halo measurement using the IPM at the Fermilab Booster
Author/Authors :
Amundson، نويسنده , , J. and Pellico، نويسنده , , W. and Spentzouris، نويسنده , , L. and Spentzouris، نويسنده , , P. and Sullivan، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
We propose a model-independent quantity, L / G , to characterize non-Gaussian tails in beam profiles observed with the Fermilab Booster Ion Profile Monitor. This quantity can be considered a measure of beam halo in the Booster. We use beam dynamics and detector simulations to demonstrate that L / G is superior to kurtosis as an experimental measurement of beam halo when realistic beam shapes, detector effects and uncertainties are taken into account. We include the rationale and method of calculation for L / G in addition to results of the experimental studies in the Booster where we show that L / G is a useful halo discriminator.
Keywords :
HALO , Ion profile monitor
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A