• Title of article

    Energy degrader technique for light-charged particle spectroscopy at LOHENGRIN

  • Author/Authors

    Oberstedt، نويسنده , , A. and Oberstedt، نويسنده , , S.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    4
  • From page
    51
  • To page
    54
  • Abstract
    The recoil mass-separator LOHENGRIN at Institute Laue-Langevin was originally designed for the spectrometry of binary fission fragments. Nevertheless, it was also used in the past for measuring light-charged particles from ternary fission. However, due to the electric field settings the energy distribution of the lightest particles was not completely accessible, which made the determination of mean kinetic energies, widths and, hence, emission yields difficult. In this paper we present an energy degrader technique that allows for the measurement of the entire energy spectrum of even the lightest ternary particles with LOHENGRIN.
  • Keywords
    Mass spectrometer , Energy distributions , Light-charged particles , Monte-Carlo simulation , energy loss , Energy degrader