Title of article
Measurement of X-ray polarization using optical imaging detector with capillary plate
Author/Authors
Sakurai، نويسنده , , H and Tokanai، نويسنده , , F and Gunji، نويسنده , , S and Motegi، نويسنده , , S and Toyokawa، نويسنده , , H and Suzuki، نويسنده , , M and Hirota، نويسنده , , K and Kishimoto، نويسنده , , S، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
6
From page
6
To page
11
Abstract
The performance of the optical imaging capillary gas proportional counter (CGPC) was investigated using polarized X-rays with an energy of 15 keV at SPring-8. The CGPC with a fill gas of Ar+8% CH4+2% TMA at 1 atm was operated at a gas gain of 15 000. The CGPC was irradiated by a polarized X-ray beam in the center region using a slit of 300 μm×300 μm. Images of single photoelectron tracks were obtained by an image-intensified CCD camera combined with the CGPC through a lens system. The average distance between the starting point and the barycenter for single photoelectron tracks was 1.1 mm. The angular distribution is obtained from the directions of the lines connected between the starting point and the barycenter for each image of the photoelectron tracks. From a least-squares fitting, the modulation factor was 25.1±2.0% for the X-rays with a polarization degree of 99%.
Keywords
Capillary plate , Photoelectron track , SPring-8 , X-ray polarization
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2004
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2202610
Link To Document