Title of article
Space-charge limitation of avalanche growth in narrow-gap resistive plate chambers
Author/Authors
Williams، نويسنده , , M.C.S، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
5
From page
168
To page
172
Abstract
A big advance in resistive plate chamber technology happened in 1996 with the advent of the multigap resistive plate chamber (MRPC). The MRPC allows us to easily construct detectors with many small gas gaps and thus we obtain good timing together with high detection efficiency. Using this technology, it is now common to build detectors with gas gaps of 200–300 μm in width. This paper examines space-charge limited avalanche growth; this becomes a dominant effect for narrow gap resistive plate chambers. This effect controls gas gain and explains the reason for the excellent behaviour of MRPCs built with this gas gap.
Keywords
MRPC , Resistive plate chambers , Multigap
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2004
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number