Title of article :
Position sensitivity of Ge detectors and its applications to in-beam nuclear spectroscopy
Author/Authors :
Shimoura، نويسنده , , S، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
For in-beam nuclear spectroscopy of projectile-like nuclei produced by nuclear reactions, we constructed an array of segmented planar-type Ge detectors at CNS, the University of Tokyo, which is capable for Doppler-shift correction of γ-rays by using position sensitivities in the detectors. The position sensitivity of the segmented planar-type Ge detector is based on pulse shapes from detectors. A method of pulse shape analysis by using an analog technique for extracting position information is discussed. Overall performance of the array is demonstrated based on recent results of an in-beam spectroscopy experiment.
Keywords :
Segmented Ge detector , Pulse shape analysis , Position sensitivity
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A